Classic Chiller Classic Chiller BundlesSetup & Support
- Step-by-step setup and operating instructions
- Connection guides for tubs with or without ports
- Troubleshooting and routine maintenance tips
- Step-by-step tub and chiller setup instructions
- Chiller controls and temperature settings
- Troubleshooting and routine maintenance tips


Set Up Your Complete Plunge System
Follow these three steps to get started: set up your tub, connect your Classic Chiller, and set your desired water temperature.
Watch the setup video for your tub model and follow along step by step. Unpack and unfold your tub, install the support tubes if included, and inflate the applicable components as shown in the video.
For included parts, setup videos, and draining instructions, visit our Tubs Only guide.Watch the setup video for your tub model and follow along step by step. Unpack and unfold your tub, install the support tubes if included, and inflate the applicable components as shown in the video.
For included parts, setup videos, and draining instructions, visit our Tubs Only guide.Watch the setup video for your tub model and follow along step by step. Unpack and unfold your tub, install the support tubes if included, and inflate the applicable components as shown in the video.
For included parts, setup videos, and draining instructions, visit our Tubs Only guide.Watch the setup video for your tub model and follow along step by step. Unpack and unfold your tub, install the support tubes if included, and inflate the applicable components as shown in the video.
For included parts, setup videos, and draining instructions, visit our Tubs Only guide.1. Connection Instructions
Watch the video and follow the connection instructions.
First hose: Connect the hose coming from the tub OUT port to the chiller IN port.
Second hose: Connect the hose coming from the tub IN port to the chiller OUT port.
2. How It Works
Water flows from the tub’s OUT port into the chiller’s IN port, then returns to the tub through the chiller’s OUT port and the tub’s IN port.
Set Your Water Temperature
Power On & Off
Follow the video to turn your Classic Chiller on and off using the control panel.
Choose Your Temperature
Use the control panel to set your desired water temperature. Follow the video for step-by-step instructions.
Understand Automatic Cooling
Cooling stops when the water reaches your set temperature and restarts when it rises by the F01 temperature differential (5°F by default).
Need help? Email support@plungechill.com with your model and a short video, or call +1 305 326 3656.
Setup Videos & Instructions
Control Panel Guide
Power On & Off
Follow the video to learn how to turn the chiller on and off using the control panel.
Set Your Temperature
Use the control panel to set your desired water temperature. Follow the video for step-by-step instructions.
Unlock the Control Panel
If the controls are locked, press and hold the Power and Down buttons together for about 5 seconds to unlock them.
Installation for Bathtub (with ports)
Connection Instructions
First hose: Connect the hose coming from the tub OUT port to the chiller IN port.
Second hose: Connect the hose coming from the tub IN port to the chiller OUT port.
How It Works
Water flows from the tub’s OUT port into the chiller’s IN port, then returns to the tub through the chiller’s OUT port and the tub’s IN port.
Tips
If water stops circulating after cleaning the filter or disconnecting the hoses, trapped air may need to be released. See “How do I release trapped air from the system?” in the Troubleshooting section below before resuming operation.
Installation for Home Bathtub (no ports)
Connection Instructions
First hose: Connect one end to the chiller’s OUT port and place the other end in the tub.
Second hose: Connect one end to the chiller’s IN port and attach the other end to the submersible pump.
How It Works
Water flows from the submersible pump through the chiller, where it is cooled, then returns to the tub.
Tips
If water is not circulating after cleaning the filter or disconnecting the hoses, release any trapped air before resuming operation. Follow the instructions under “How do I release trapped air from the system?” in the Troubleshooting section below.
Get to Know Your Chiller
-
Overview
Get familiar with your chiller.
-
Specifications
Check dimensions, power, and cooling capacity.
-
What's Included
See what comes with your chiller.
-
How Your Chiller Works
Learn how your chiller filters, cools, and circulates water to maintain your set temperature.
Troubleshooting
My Chiller Isn’t Cooling the Water
If your chiller is running and the water is circulating, but the temperature is not dropping as expected, follow the steps below to identify and resolve the issue.
1. Ensure Proper Operation: Confirm that the chiller is turned on and the water is circulating correctly. If you don't have water flow then first read this article: Why is my water not circulating?
2. Adjust Temperature Settings:
- Press & hold the POWER button to turn the unit ON.
- Adjust the temperature up or down using the arrow buttons.
The chiller should start cooling and you should hear the compressor running within 3-5 minutes. If not, proceed to the next steps.
If you keep having issues then click on this link: Contact form or contact our customer support team directly on support@plungechill.com
Why Is My Water Not Circulating?
It sounds like your chiller is running, but you’re having trouble with water circulation. Let’s work through a few steps to resolve this issue:
1. Check the Filter:
- Make sure the filter is clean and properly installed. We recommend cleaning it every two weeks, depending on usage and water condition. If you haven’t cleaned your filter recently, it might be the cause of the problem. You can follow this guide to cleaning your water filter for detailed instructions.
2. Review the Setup
- Confirm that the system has been connected according to our Setup Guide, with the hoses connected to the correct IN and OUT ports.
- Make sure the hoses are not bent or blocked, all applicable tub valves are open, and all connections are securely tightened.
- Check that the O-ring is correctly installed on the filter housing.
3. Remove Trapped Air
- Disconnect the hose from the chiller’s OUT port, then turn on the chiller until water flows steadily from the OUT port.
- Turn off the chiller and reconnect the hose securely to the OUT port.
Note: If the temperature on your display drops quickly but the water in the tub isn’t cooling, it’s a sign that the chiller is working, but the water circulation needs adjustment.
Cooling Performance Is Lower Than Expected
- High ambient temperatures can increase cooling time.
- Place the chiller in a shaded, well-ventilated area.
- Keep enough clearance around the air vents.
- Reduce the amount of water when appropriate.
- Set a lower target temperature.
- Keep the tub cover securely closed.
- Allow sufficient time for the water to reach the target temperature.
The Screen Displays “OFF”
If the screen shows “OFF,” the chiller is in standby mode. Unlock the screen first: hold ▲ + ▼ together for 3 seconds, then press the Power button to start.
Why is my chiller display blank?
1. Make sure the chiller is plugged into a working electrical outlet.
2. Turn on the main power switch on the back of the chiller.
3. Press and hold the Power button on the control panel to turn on the unit.
If the display remains blank, contact us at support@plungechill.com.
Why isn't the power button responding?
1. Check that the chiller is plugged into a working outlet.
2. Make sure the main power switch on the back is turned on.
If the unit still doesn't respond, record a short video showing the issue and email it to support@plungechill.com.
What do the F01 and F02 settings do?
F01 — Temperature Deviation
Controls how far the water temperature rises above your target before cooling restarts.
- Range: 1–27°F
- Default: 5°F
- Example: If your target is 45°F, cooling restarts at 50°F.
To adjust: Hold Up + Down → press Power to select F01 → adjust with Up or Down → press Power to confirm.
Keep the recommended 5°F setting. Setting it too low may cause frequent compressor cycling.
F02 — Temperature Calibration
Adjusts the displayed temperature. Normally, leave it at 0°F.
To check: Hold Up + Down → press Down to reach F02 → press Power to view the value.
If the reading is still inaccurate at 0°F, contact support before making changes.
The panel exits Function Mode after about 10 seconds of inactivity.
Why is my chiller leaking?
Turn off and unplug the chiller before checking connections.
1. Check that the filter housing O-ring is present, undamaged, and seated evenly.
2. Apply PTFE (plumber's) tape to threaded fittings that require thread sealing. Keep tape off O-ring sealing surfaces.
3. Hand-tighten fittings without overtightening. Push hoses fully onto their connectors and secure the clamps.
4. Wipe the area dry. Scattered droplets may be condensation; repeated dripping from one connection may indicate a leak.
If leaking continues, send a short video of the affected area to support@plungechill.com.
Water Droplets on the Chiller Surface
Small water droplets on the outside of the chiller are usually condensation. This happens when warm, humid air comes into contact with the cold surface of the chiller. Wipe the surface dry and check whether the chiller is cooling normally. If it is cooling properly and no continuous water leak is found, this is normal condensation.
What should I do if my tub is leaking?
Stop using the tub and record a short video clearly showing where the water is leaking.
Email the video to support@plungechill.com with a brief description of the issue. Our support team will help you with the next steps.
Why is my water chiller pump & filter shaking / making a loud noise?
If your water chiller's pump is making a loud noise, it’s often due to air in the system or a lack of water flow. Here's how to address the issue and get your pump operating quietly again:
1. Check the Filter and Circulation:
- First, determine when you last cleaned your filter. Regular maintenance is crucial. Follow our filter cleaning video for step-by-step instructions.
2. Verify and Fix Connections:
- Make sure Teflon tape is applied to all threaded connections.
- Check that the O-ring is correctly installed in the filter housing.
- Reconnect the hoses and securely tighten all connections.
3. Remove Trapped Air
- Disconnect the hose from the chiller’s OUT port, then turn on the chiller until water flows steadily from the OUT port.
- Turn off the chiller and reconnect the hose securely to the OUT port.
4. Power Up:
- Plug your chiller back in and turn it on. The pump should now operate quietly once it has a steady flow of water.
Why is my water circulation slow?
If you’re experiencing slow water circulation, it’s often due to a clogged filter. Here’s how you can address and resolve the issue:
Clogged Filter: Over time, dirt and debris can clog the filter, which reduces water flow to the tubs or stops it completely. Cleaning the filter should help restore proper circulation.
How do I release trapped air from the system?
Make sure the tub water level is above the chiller's OUT port but below the tub's IN port.
1. Turn off the chiller and disconnect the hose from its OUT port.
2. Open both tub valves (IN and OUT).
3. Turn on the chiller.
4. Let the pump run briefly until water flows steadily from the chiller's OUT port.
5. Turn off the chiller.
6. Reconnect the hose securely to the OUT port.
Important: Do not let the pump run dry.
How do I clean the built-in filter?
1. Turn off and unplug the chiller.
2. Turn the filter cover counterclockwise to remove it.
3. Remove the metal filter and rinse it thoroughly under running water.
4. Reinsert the clean filter and turn the cover clockwise to secure it. Do not overtighten.
Clean the filter approximately every two weeks, or more often depending on water conditions.
Run the noise test
To help us determine whether the noise is within the normal operating range:
- Download a sound meter app:
iPhone: NIOSH Sound Level Meter
Android: Sound Meter or Decibel X - Measure the noise from about 3 ft (1 m) away for at least 30 seconds while the chiller is running.
- Turn off nearby noise sources for a more accurate reading.
- Send us a short video showing the chiller running and the dB reading.
Our technical team will review the results. If the noise is confirmed to be abnormal and cannot be resolved, we’ll provide an appropriate solution, including replacement if necessary.
How do I send photos or videos to customer support?
Email support@plungechill.com with:
- Your order number
- A brief description of the issue
- Clear photos or a short video showing the problem
If your video is too large to attach, upload it to Google Drive and include a shareable link in your email.
Our support team will review the information and assist you with the next steps.
Send photos or video of a missing or damaged part
Email photos or a short video of the affected parts to support@plungechill.com, together with your product model and a description of what is missing or damaged.
Still need help?
Our support team is happy to help. Send your model and a short video so we can solve it faster.